Home / Industrial / RediBar

RediBar

Pre-Assembled, Ready-to Install Enclosed Conductor Bar System

REDI-BAR is a factory-assembled, ready-to-install conductor bar system designed to simplify crane conductor installations and replacements from 64 amps up to 480 amps. With an installation that can be completed in just a few hours, REDI-BAR can be installed quickly and easily with minimal downtime. Standard 4-pole conductor bar assemblies are available off-the-shelf, while custom conductor bar assemblies are manufactured to order for unique applications.

redibar-product-diagram

Specifications

  • Standard 4-pole copper conductor configuration (3 phases plus ground)
  • Up to 660 volt (AC and DC) and 480 amp capacity configurations
  • 64, 100, 160 and 240 amp 3-phase plus ground
  • 320 and 480 amp achieved with parallel phase conductors plus single ground (1/2 amperage ground)
  • UL and CSA approved
  • 4 meter, 2 meter and 1 meter standard bar lengths, custom lengths available
  • Standard isolation section available
  • Custom conductor configurations possible
  • Temperature range: -22°F to 158°F continuous

Configuration is Easy

Configuring a REDI-BAR system is very easy and can be completed with only basic information regarding the input power requirements and conductor bar length.

STEP ONE: REDI-BAR System Selection

  1. Select the appropriate chart below based on the power requirements of your crane, 480VAC or 250VDC (for other power systems, please contact TransTech for assistance)
  2. On the vertical axis of the chart, plot your maximum current load
  3. On the horizontal axis, plot your system length in meters (1 meter = 3.3 feet); if longer than 200 meters, please contact TransTech
  4. Note the colored region where these two plots intersect; this determines which REDI-BAR series is required

redibar-product-graph1

redibar-product-graph2

STEP TWO: Determine Required Components

  1. Once the REDI-BAR series is determined, select a 4m Starter Kit
    1. For 64 or 100 series REDI-BAR systems:
      • If an end power feed is required select the End Feed Starter Kit
      • If the feed point is located elsewhere on the system, select the Line Feed Starter Kit
    2. For 160 to 480 series REDI-BAR systems, select the Line Feed Starter Kit (which can also be used as an end feed)
SeriesLine Feed Starter Kit (4m)End Feed Starter Kit (4m)
number_64 RBS4064 RBE4064
number_100 RBS4100 RBE4100
number_160 RBS4160 N/A
number_240 RBS4240 N/A
number_320 RBS4320 N/A
number_480 RBS4480 N/A
  1. Determine the number of Add-on Kits required based on length; the total of all Add-on Kits should be 4 meters less than the desired system length since the Starter Kit is 4 meters long
    1. For example, for a 23 meter long system, 19 meters of Add-On Kits are required:
      • 4m Add-on Kit (quantity 4 required)
      • 2m Add-on Kit (quantity 1 required)
      • 1m Add-on Kit (quantity 1 required)
SeriesAdd-on Kit (4m)Add-on Kit (2m)Add-on Kit (1m)
number_64 RBA4064 RBA2064 RBA1064
number_100 RBA4100 RBA2100 RBA1100
number_160 RBA4160 RBA2160 RBA1160
number_240 RBA4240 RBA2240 RBA1240
number_320 RBA4320 RBA2320 RBA1320
number_480 RBA4480 RBA2480 RBA1480
  1. Determine the number of trolley collectors required to carry the current load by dividing the required current load by the collector current capacity from the chart and rounding up
    1. For example, for a 90A current load using 100 series REDI-BAR, three 40A trolleys are required (90 ÷ 40 = 2.25, round up to 3)
SeriesCollector TrolleyCurrent Capacity
number_64 RB94041 40A
number_100 RB94041 40A
number_160 RB94041 40A
number_240 RB94041 40A
number_320 RB94171 100A
number_480 RB94171 100A
    ba0f-redibar-product-application.jpg