Pre-Assembled, Ready-to Install Enclosed Conductor Bar System
REDI-BAR is a factory-assembled, ready-to-install conductor bar system designed to simplify crane conductor installations and replacements from 64 amps up to 480 amps. With an installation that can be completed in just a few hours, REDI-BAR can be installed quickly and easily with minimal downtime. Standard 4-pole conductor bar assemblies are available off-the-shelf, while custom conductor bar assemblies are manufactured to order for unique applications.
Specifications
Standard 4-pole copper conductor configuration (3 phases plus ground)
Up to 660 volt (AC and DC) and 480 amp capacity configurations
64, 100, 160 and 240 amp 3-phase plus ground
320 and 480 amp achieved with parallel phase conductors plus single ground (1/2 amperage ground)
UL and CSA approved
4 meter, 2 meter and 1 meter standard bar lengths, custom lengths available
Standard isolation section available
Custom conductor configurations possible
Temperature range: -22°F to 158°F continuous
Configuration is Easy
Configuring a REDI-BAR system is very easy and can be completed with only basic information regarding the input power requirements and conductor bar length.
STEP ONE: REDI-BAR System Selection
Select the appropriate chart below based on the power requirements of your crane, 480VAC or 250VDC (for other power systems, please contact TransTech for assistance)
On the vertical axis of the chart, plot your maximum current load
On the horizontal axis, plot your system length in meters (1 meter = 3.3 feet); if longer than 200 meters, please contact TransTech
Note the colored region where these two plots intersect; this determines which REDI-BAR series is required
STEP TWO: Determine Required Components
Once the REDI-BAR series is determined, select a 4m Starter Kit
For 64 or 100 series REDI-BAR systems:
If an end power feed is required select the End Feed Starter Kit
If the feed point is located elsewhere on the system, select the Line Feed Starter Kit
For 160 to 480 series REDI-BAR systems, select the Line Feed Starter Kit (which can also be used as an end feed)
Series
Line Feed Starter Kit (4m)
End Feed Starter Kit (4m)
RBS4064
RBE4064
RBS4100
RBE4100
RBS4160
N/A
RBS4240
N/A
RBS4320
N/A
RBS4480
N/A
Determine the number of Add-on Kits required based on length; the total of all Add-on Kits should be 4 meters less than the desired system length since the Starter Kit is 4 meters long
For example, for a 23 meter long system, 19 meters of Add-On Kits are required:
4m Add-on Kit (quantity 4 required)
2m Add-on Kit (quantity 1 required)
1m Add-on Kit (quantity 1 required)
Series
Add-on Kit (4m)
Add-on Kit (2m)
Add-on Kit (1m)
RBA4064
RBA2064
RBA1064
RBA4100
RBA2100
RBA1100
RBA4160
RBA2160
RBA1160
RBA4240
RBA2240
RBA1240
RBA4320
RBA2320
RBA1320
RBA4480
RBA2480
RBA1480
Determine the number of trolley collectors required to carry the current load by dividing the required current load by the collector current capacity from the chart and rounding up
For example, for a 90A current load using 100 series REDI-BAR, three 40A trolleys are required (90 ÷ 40 = 2.25, round up to 3)